Min-Gyo Jeong, Ji-Hong Kim, Sang-Hyeon Bae, and Wang-Sang Lee
2017 IEEE MTT-S International Microwave Symposium (IMS2017)


A four-port feeding network of hybrid couplers and delay lines drives a chosen line differentially, so UHF RFID tags on a smart shelf can be located section by section.
Depending on magnetic fields caused by phase differences between the adjacent transmission lines for high precision UHF near-field sectional localization systems, a four-port selective differential feeding network is presented. The proposed four-port feeding network consisting of four quadrature hybrid couplers and 90° phase delay lines can selectively generate a differential phased current on a particular transmission line. The maximum insertion loss within the authorized UHF RFID frequency band (902-928MHz) has a 7.1dB loss including the theoretical 6dB power distribution loss, and the maximum amplitude imbalances and phase error have less than ±0.5dB and ±10°, respectively. By switching the input ports, the sectional identification with regard to tag positions on the 10 mm height away from parallel transmission lines can be achieved. The proposed system using a four-port selective differential feeding network makes it possible to utilize a near-field position detection application such as a smart shelf.
하이브리드 커플러와 지연선으로 원하는 선로에 차동 전류를 거는 4포트 급전망으로, 스마트 선반 위 UHF RFID 태그의 위치를 구역별로 찾는다.
Depending on magnetic fields caused by phase differences between the adjacent transmission lines for high precision UHF near-field sectional localization systems, a four-port selective differential feeding network is presented. The proposed four-port feeding network consisting of four quadrature hybrid couplers and 90° phase delay lines can selectively generate a differential phased current on a particular transmission line. The maximum insertion loss within the authorized UHF RFID frequency band (902-928MHz) has a 7.1dB loss including the theoretical 6dB power distribution loss, and the maximum amplitude imbalances and phase error have less than ±0.5dB and ±10°, respectively. By switching the input ports, the sectional identification with regard to tag positions on the 10 mm height away from parallel transmission lines can be achieved. The proposed system using a four-port selective differential feeding network makes it possible to utilize a near-field position detection application such as a smart shelf.
The abstract is from the published paper (doi:10.1109/mwsym.2017.8058930).초록은 출판된 논문(doi:10.1109/mwsym.2017.8058930)에서 옮겼습니다.